20

Part 1 Installation

[6] Encoder/axis-sensor

connector

This connector is used to connect the actuator encoder and axis sensors such
as LS, CREEP and OT. * LS, CREEP and OT sensors are optional.
The connectors are assigned to axis 1, axis 2, and so on, from the right.

Encoder/Axis-sensor Connector Specifications

Item Overview

Details

Connector

Half-pitch, 26-pin
I/O connector

10226-6202JL (by Sumitomo 3M)

Cable-end
connector

10126-3000VE (by Sumitomo 3M)
(Hood: 10326-52F0-008)

Connector name

PG1 ~ 6

Encoder/axis-sensor connector

Maximum wiring
distance

30 m

Pin

No.

Signal

name

Description

Signal table

1
2
3
4
5
6

7

SRD+

Send/receive differential +
(pulse/magnetic pole switching +)

8

SRD–

Send/receive differential -
(pulse/magnetic pole switching -)

9

NC

Not connected

10

NC

Not connected

11

NC

Not connected

12

24VOUT

Sensor power output

13

0V

24-V power ground

14

BATT

Backup battery

15

BATTGND Battery

ground

16

VCC

Encoder

power

17

GND

GND

18

NC

Not connected

19

NC

Not connected

20

BK–

Brake open output signal - (COM:
Common to all axes)

21

BK+

Brake open output signal +

22

NC

Not connected

23

*RSV

Sensor input RSV

24

*OT

Sensor input OT

25

*CLEEP

Sensor input CLEEP

26

*LS

Sensor input LS

Advertising