135

Part 4 Commands

RC Gateway Function Commands (Controllers with Gateway Function Only)

* For the RC gateway function commands, refer to “Operation Manual for X-SEL Controller P/Q/PX/QX

RC Gateway Function.”

Operation type in the output field
CC:

Command was executed successfully,

ZR:

Operation result is zero, PE: Operation is complete,

CP:

Command part has passed, TU: Time up

EQ:

Operand 1 = Operand 2, NE: Operand 1

z Operand 2,

GT:

Operand 1 > Operand 2, GE: Operand 1

t Operand 2,

LT:

Operand 1 < Operand 2, LE: Operand 1

d Operand 2

RC position

data use mode

Category

Condition

Command

In X-

SEL

In RC

Operand 1

Operand 2

Output

Function

Optional RPGT

{

X

RC axis number

Position number

CC

Assign RC axis position to
variable 199

Optional RPPT

{

X

RC axis number

Position number

CP

Assign variable 199 to RC axis
position

Optional RPCR

{

X

RC axis number

Variable number

CP

Clear RC axis position data

Optional RPCP

{

X

RC axis number

Variable number

CP

Copy RC axis position data

Optional RPRD

{

X

Position number

Prohibited

CP

Read current RC axis position

Optional RPRQ

{

{

RC axis number

Variable number

CP

Read current RC axis position (1
axis, direct)

Optional RPVL

{

X

RC axis number

Position number

CP

Assign variable 199 to RC axis
position speed

Optional RPAD

{

X

RC axis number

Position number

CP

Assign variable 199 to RC axis
position acceleration/deceleration

Optional RPIP

{

X

RC axis number

Position number

CP

Assign variable 199 to RC axis
position positioning band

Optional RPTQ

{

X

RC axis number

Position number

CP

Assign variable 199 to RC axis
position current-limiting value

Optional RGVL

{

X

RC axis number

Position number

CP

Assign RC axis position speed to
variable 199

Optional RGAD

{

X

RC axis number

Position number

CP

Assign RC axis position
acceleration/deceleration to
variable 199

Optional RGIP

{

X

RC axis number

Position number

CP

Assign RC axis position
positioning band to variable 199

RC axis
position

operation

Optional RGTQ

{

X

RC axis number

Position number

CP

Assign RC axis position current-
limiting value to variable 199

Optional RAXS

{

{

Axis pattern, upper

Axis pattern,
lower

CP

Set RC axis pattern

Optional RSON

{

{

Prohibited

Prohibited

PE

Turn RC axis servo ON

Optional RSOF

{

{

Prohibited

Prohibited

PE

Turn RC axis servo OFF

Optional RHOM

{

{

Prohibited

Prohibited

PE

Return RC axis to its home

Optional RMVP

{

{

Position number

Prohibited

PE

Move by RC axis position
specification

Optional RMPI

{

X

Position number

Prohibited

PE

Incremental move by RC axis
position specification

Optional RMVD

{

X

RC axis number

Variable number

PE

Move by RC axis direct
specification

Optional RMDI

{

X

RC axis number

Variable number

PE

Incremental move by RC axis
direct specification

Optional RPUS

{

X

RC axis number

Position number

PE

Move by RC axis push-motion
operation

RC

actuator

control

command

Optional RSTP

{

{

Prohibited

Prohibited

PE

Decelerate RC axis to stop

RC axis

information

acquisition

Optional RCST

{

{

Variable number

RC axis number

PE

Get RC axis status

Advertising