IAI America XSEL-QX User Manual

Page 476

Advertising
background image

452

Appendix

Axis-Specific Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

51 Gear

ratio

numerator

50,
50,
10,
15,

1,

1

1 ~ 99999999

Reference only

for SCARA axes

(axes 1 to 4)

52 (For

extension)

0

53 Setting bit pattern 1 of

each axis

0 0H

~

FFFFFFFFH

Bits 0 to 3: For future extension

54 Travel distance for push-

motion stop detection at
movement to absolute
reset position/home return

20

1 ~ 99999

0.001 mm

Used for confirmation of push motion operation at
movement to absolute reset position/home return.
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))

55 Travel distance for push-

motion stop detection at
positioning

30

1 ~ 99999

0.001 mm

Used for confirmation of push motion operation
effected by a PUSH command.
(Used for SCARA axis 3 (Zc) and linear
movement axes (axes 5 and 6 (6-axis type)))

56 Deviation ratio for forced

push-motion completion at
movement to absolute
reset position/home return

5000

1 ~ 99999

Deviation is compared against “Steady-state
deviation of push speed + Push-speed pulse
speed x Abort deviation ratio.” (Used only for axis
3 (Zc))

57 Push-abort deviation ratio

at positioning

3000

1 ~ 99999

Deviation is compared against “Steady-state
deviation of push speed + Push-speed pulse
speed x Abort deviation ratio.”

58 Positioning

band

50,
50,

100,
150,
100,

100

1 ~ 9999

0.001 mm,

0.001 deg

59 Allowable deviation error

ratio
(Maximum speed pulse
ratio)

85

Reference only

For adjustment by the manufacturer

60 PPG (Position gain)

60,
60,
60,
60,
30,

30

1 ~ 9999

* Change is prohibited for SCARA axes (axes 1 to

4) unless instructed by the manufacturer.

61 PFAG

0

0 ~ 999

* Change is prohibited for SCARA axes (axes 1 to

4) unless instructed by the manufacturer.

62 Linear movement axis

synchro FB gain

0,
0,
0,
0,

77,

77

1 ~ 1000

Reference only

for SCARA axes

(axes 1 to 4)

* Valid for linear movement axes (axes 5 and 6 (6-

axis type)) only.

(Main application version 0.12 or later)

63 Stop special output range

1

0 ~ 9999

Pulse

Invalid if “0” is set.

64 Stop special output value

1

0 ~ 999

DRVVR

65 Mating

synchro-axis

number (linear movement
axis)

0

0 ~ 8

Reference only

for SCARA axes

(axes 1 to 4)

Must be input for both axes. (Of the axis pair, the
axis with the smaller axis number becomes the
master axis. Both axes must have the same
resolution characteristics. Commands cannot be
issued to the slave axis.) (Invalid if “0” is set)
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.
(Main application version 0.15 or later)

66 Mode selection for

rotational movement axis
(linear movement axis)

0

0 ~ 5

Reference only

for SCARA axes

(axes 1 to 4)

0: Normal, 1: Index mode
* Valid for linear movement axes (axes 5 and 6

(6-axis type)) only.

(Main application version 0.12 or later)

Advertising