339

Part 4 Commands

(2) Positioning on the load coordinate system

Perform positioning after selecting a desired load coordinate system.
Use a SLWK command to select a load coordinate system number in a SEL program.
The selected load coordinate system number will remain valid after the program ends, and even
after reconnection of power if a system-memory backup battery is installed.

[1] When positioning to position Nos. 5 and 6 in PTP mode on load coordinate system No. 1

Program example

:

:

:

SLWK

1

Select load coordinate
system No. 1.

SLTL 0 Select

tool

coordinate

system No. 0.

PTPR

Specify the right arm as the
PTP target arm system.

MOVP

5

Move to position No. 5.

MOVP

6

Move to position No. 6.

:

:

:

The R-axis position will be as shown in the
figure at left (top view).
The Z-axis position will be as follows:
Position No. 5: Zb = 0
Position No. 6: Zb = 20

Position No. 5

Position No. 6

200

Yw1

Xw1

50

D-cut surface
of R-axis

Position No. 6

Position No. 5

Yw1

Xw1

30

q

50

Yb

Xb

40

q

200