IAI America XSEL-QX User Manual

Page 453

Advertising
background image

429

Appendix

No. Parameter

name

Default

value

(Reference)

Input range

Unit

Remarks

24 I/O setting bit pattern 1

(Related to global
specifications)

10000H 0H

~

FFFFFFFFH

Bits 0 to 3:

RDY OUT function selection (System IO)
(0: SYSRDY (Software = PIO trigger
program can be run) and hardware is
normal (emergency stop has not be
actuated and hardware error is not
present)
1: Error of operation-cancellation level

or higher is not present

2: Error of cold-start level or higher is

not present

Bits 4 to 7:

RDY LED function selection
(0: Program can be run
1: Error of operation-cancellation level

or higher is not present

2: Error of cold-start level or higher is

not present)

Bits 8 to 11:

DET (MELT) (melted drive-source cutoff
relay) signal enable selection (0: Disable,
1: Enable)

Bits 12 to 15: Drive-source cutoff relay DET (MELT)

error level (when low voltage cannot be
checked)
(0: Cold start, 1: Message)

Bits 16 to 19: Drive-source cutoff relay DET (MELT)

error level (when low voltage cannot be
checked)
(0: Cold start, 1: Message)

25 I/O setting bit pattern 2

(Related to global
specifications)

0H 0H

~

FFFFFFFFH

Bits 0 to 3: For future extension
Bits 4 to 7: For future extension

26~

28

(For extension)

0

29 Physical output port

number for drive-source
cutoff (SDN) notification

0

0 ~ 599

Turn the output port OFF when the drive source is cut
off
(* Important: This is only a software notification output)
(Invalid if “0” is set)
* Note: Enter a hexadecimal value if the tool (PC

software or TP) is of a version where input areas
are indicated by “h” notation.