IAI America XSEL-QX User Manual

Page 452

Advertising
background image

428

Appendix

No. Parameter

name

Default

value

(Reference)

Input range

Unit

Remarks

13 Expanded I/O3 error

monitor (I/O4)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power-supply

errors)

3: Monitor (Monitor 24-V I/O power-supply errors only)
* Some exceptions apply.
* If 0 (= Do not monitor) or 2 (= Monitor (Do not monitor

24-V I/O power-supply errors)) is selected, a system
error will not generate when a 24-V I/O power-supply
error occurs. To protect the controller, however, the
actual outputs of the digital I/O board will be cut off by a
circuit later.

14 Number of ports using

network I/F module
remote input

0

0 ~ 256

Multiple of 8

15 Number of ports using

network I/F module
remote output

0

0 ~ 256

Multiple of 8

16 Input port start number

when network I/F
module assignments are
fixed

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

17 Output port start number

when network I/F
module assignments are
fixed

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

18 Network I/F module error

monitor

1

0 ~ 5

0: Do not monitor
1: Monitor
* Some exceptions apply.

19 (For

extension)

0

20 Input filtering periods

2

1 ~ 9

msec

Input signal is recognized when the status is held for
twice the period set by this parameter.

21 For future extension

(Change prohibited)

0

1 ~ 9

22 Remote-I/O-card

fieldbus

ready timeout value

2000

0 ~ 99999

msec

Timeout check is not performed if “0” is set.

23 Input specification for

detection of
overcurrent/abnormal
power supply for multi-
point DIO external
terminal block

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Standard I/O (I/O1) input specification

Bits 4 to 7:

Expanded I/O1 (I/O2) input specification

Bits 8 to 11:

Expanded I/O2 (I/O3) input specification

Bits 12 to 15: Expanded I/O3 (I/O4) input specification

(0: Do not input error detection signal
1: Input error detection signal = IN023 in

card

2: Input error detection signal = IN047 in

card

3: Input error detection signal =

IN023/47 in card)

* Set this parameter after confirming the specification

of the multi-point DIO terminal block unit to be
connected.

* Input ports used for error detection input cannot be

used as general-purpose input ports.