464

Appendix

7. Other

Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1 Auto-start

program

number

0

0 ~ 64

(Invalid if “0” is set)

2

I/O processing program
number at
operation/program abort

0

0 ~ 64

The start trigger is determined from the “I/O processing
program start type at operation/program abort.” (Note:
This program will be started before confirming an abort
of other programs.)
(Invalid if “0” is set) * If the setting is valid, the number of
user program tasks that can be used will decrease by 1.

3

I/O processing program
number at all operation
pause

0

0 ~ 64

This program will be started when an all-operation-
pause command is issued due to an all-operation-pause
factor. (Only when a program is running) (Invalid if “0” is
set) * If the setting is valid, the number of user program
tasks that can be used will decrease by 1.

4

Program abort type at
error

0

0 ~ 5

0: Cancel only the program in which an error of

operation-cancellation level or higher has generated.
(If the error requires the drive source to be cut off,
servo OFF or all-axis servo OFF, all programs other
than the “I/O processing program at
operation/program abort” will be cancelled.)

1: Cancel all programs other than the “I/O processing

program at operation/program abort” when an error
of operation-cancellation level or higher has
generated.

5

I/O processing program
start type at
operation/program abort

0

0 ~ 5

0: When all-operation-cancellation factor has generated

(Only when a program is running)

1: When all-operation-cancellation factor has generated

(Always)

2: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4
= 0” is considered) (Only when a program is running)

3: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4
= 0” is considered) (Always)

6 PC/TP

reconnection

delay at software reset

14000

1 ~ 99999

msec

* The setting will become effective after the controller,

PC software or TP is restarted.

7~8 (For

extension)

0

9

For future extension
(Change prohibited)

0

0 ~ 9

10 Emergency-stop

recovery type

0

0 ~ 4

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic

operation.

* Operation commands from the PC software/TP will

be aborted from the PC software/TP side.)

3: Abort operations/programs (Software reset when the

emergency stop is reset. The home-return
completion status of incremental-encoder axes will
be reset (EG approximation swap)).

4: Abort operations/programs (Error reset (only with an

error of operation-cancellation level or lower) and
auto-start program start (only if AUTO mode AND I/O
parameter No. 33 = 1 AND I/O parameter No. 44

z 1

AND all-operation-cancellation factor is not present)
when the emergency stop is reset). There must be a
minimum interval of 1 second after an emergency
stop is actuated before it is reset. The home-return
completion status of incremental-encoder axes will
be retained.)

11

Enable switch (deadman
switch/enable switch)
recovery type

0

0 ~ 2

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic

operation. * Operation commands from the PC
software/TP will be aborted from the PC software/TP
side.)

PC: PC

software

TP: Teaching

pendant