Appendix

3. Axis-Specific

Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1

Axis operation type

1,
1,
0,
1,
0,

0

0 or 1

Reference only

for SCARA axes

(axes 1 to 4)

0: Linear movement axis, 1: Rotational movement

axis (angle control)
(Change is prohibited for SCARA axes (axes 1 to
4))

2 ~

5

(For extension)

0

~

6 Coordinate/physical

operation direction
selection

1,
1,
0,
0,
1,

1

0 or 1

Reference only

for SCARA axes

(axes 1 to 4)

0: Motor CCW

o Positive direction on the

coordinate system

1: Motor CCW

o Negative direction on the

coordinate system

7

Soft limit +

210000,
145000,
200000,
720000,

50000,

50000

-99999999 ~

99999999

0.001

mm,

0.001 deg

Fixed to 359.999 degrees internally for linear
movement axes (axes 5 and 6 (6-axis type)) in the
index mode
Invalid in the infinite-stroke mode.

8

Soft limit –

-30000,

-145000,

0,

-720000,

0,

0

-99999999 ~

99999999

0.001

mm,

0.001 deg

Fixed to degree internally for linear movement axes
(axes 5 and 6 (6-axis type)) in the index mode
Invalid in the infinite-stroke mode.

9

Soft-limit actual position
margin

1000,
1000,
1000,
1000,
2000,

2000

0 ~ 9999

0.001

mm,

0.001 deg

This parameter indicates the actual position margin
for the critical positioning boundary zone for linear
movement axes (axes 5 and 6 (6-axis type)) in the
infinite-stroke mode.

10 Method of movement to

absolute reset
position/home return

0

0 ~ 5

Reference only

for SCARA axes

(axes 1 to 4)

0: Search for phase Z after end search
1: Current position = 0 home

(This can be specified for an incremental
encoder only. Pay attention to interference.)

2: Set the current position as the preset home

(This can be specified for an incremental
encoder only. Pay attention to interference.)

(Change is prohibited for SCARA axes (axes 1 to
4))

11 End-search

direction

selection at movement to
absolute reset
position/home return

0

0 or 1

Reference only

for SCARA axes

(axes 1 to 4)

0: Negative end of the coordinate system
1: Positive end of the coordinate system

(Used for SCARA axis 3 (Zc) and linear movement
axes (axes 5 and 6 (6-axis type)))

12 Home preset value

90000,

0,
0,

-90000,

0,

0

-99999999 ~

99999999

Reference only

for SCARA axes

(axes 1 to 4)

0.001

mm,

0.001 deg

13 Sequence of SIO/PIO

movement to absolute
reset position/home
return

0

0 ~ 16

Reference only

for SCARA axes

(axes 1 to 4)

Executed sequentially from the smallest number.
* Valid for linear movement axes (axes 5 and 6 (6-

axis type)) only.