IAI America XSEL-QX User Manual

Page 489

Advertising
background image

465

Appendix

Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

12 Automatic

operation

recognition type

0

0 ~ 3

0: Program is running AND all-operation-cancellation

factor is not present

1: [Program is running OR in AUTO mode] AND all-

operation-cancellation factor is not present

13~

19

(For extension)

0

20 System-memory

backup battery
installation function
type

2

0 ~ 2

0: Not installed (SEL global data/error lists cannot

be recovered from the flash ROM)

1: Not installed (SEL global data/error lists can be

recovered from the flash ROM)

2: Installed

* When the power is turned on without battery

installed, point data can be copied from the
flash ROM.

* Use of setting “1” will be prohibited for the time

being due to limitations.

* When point data is lost due to a battery error,

the point data valid before the flash ROM was
written can be restored

o Input “0” (not

installed) and transfer the setting to the
controller, and then perform a software reset
without writing the flash ROM. The point data
last written to the flash ROM will be restored.
Thereafter, reset this parameter to the original
value. (No remedy is available for recovery of
SEL global data/error lists.)

21 Manual operation type

0

0 ~ 5

0: Always enable edit and SIO/PIO start (Initial

condition after connection = With safety speed)

1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial

condition after connection = Without safety speed
(cancellation))

* Referenced by the PC/TP.

22 Control use region

0

0 ~ 99

0: J, 1: E, 2: EU

23 PSIZ

command

function type

0

0 ~ 5

0: Maximum number of point data areas
1: Number of point data used

24 Local variable number

for storing SEL-
communication-
command return code

99

1 ~ 99,

1001 ~ 1099

25~

29

(For extension)

0

30 Option Password 00

0H

0H ~

FFFFFFFFH

HOME command option (Change prohibited)

* Change is prohibited unless instructed by the

manufacturer.

31 Option Password 01

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)
* Change is prohibited unless instructed by the

manufacturer.

32 Option Password 02

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)
* Change is prohibited unless instructed by the

manufacturer.

33~

35

(For extension)

0

0H ~

FFFFFFFFH

Advertising