Caution – IAI America XSEL-QX User Manual

Page 65

Advertising
background image

41

Part 1 Installation

(2) Output

part

External Output Specifications

Item

Specification

Load voltage

24 VDC

Maximum load current 100 mA per point, 400 mA per 8 ports Note)

Leakage current

0.1 mA max. per point

TD62784 (or equivalent)

Insulation method

Photocoupler insulation

External devices

[1] Miniature

relay

[2] Sequencer input unit

Note) 400 mA is the maximum total load current of every eight ports from output port No. 300 (the maximum total

load current of output port No. 300 + n to No. 300 + n + 7 is 400 mA, where n is 0 or a multiple of 8).

[Output circuit]

* P24: I/O interface pin No. 1
* N: I/O interface pin No. 50

Caution

In the event that the load is short-circuited, the overcurrent protection circuit will cut the
power. However, give due consideration to the circuit connection layout to prevent a
short-circuit or overcurrent.

Internal cir

cuit

10

:

N

P24

Surge absorber

Output terminal

Load

External power supply
24 VDC

10%

+

-