Part 4 Commands

[2] When positioning to position Nos. 5 and 6 in PTP mode on load coordinate system No. 2

Program example

:

:
:
SLWK

2

Select load coordinate
system No. 2.

SLTL 0 Select

tool

coordinate

system No. 0.

PTPR

Specify the right arm as the
PTP target arm system.

MOVP

5

Move to position No. 5.

MOVP

6

Move to position No. 6.

:

:

:

The R-axis position will be as shown in the
figure at left (top view).
The Z-axis position will be as follows:
Position No. 5: Zb = 25
Position No. 6: Zb = 45

Position No. 6

Position No. 5

200

Yw2

Xw2

50

D-cut surface of R-axis

Position No. 6

Position No. 5

Yw2

Xw2

–20

q

50

Yb

Xb

40

q

200

(- direction)