IAI America XSEL-QX User Manual

Page 42

Advertising
background image

18

Part 1 Installation

[1] FG

terminal

This terminal is used to ground FG on the enclosure. The enclosure is

connected to PE in the AC input part inside the controller.

FG Terminal Specifications

Item Description

M4 3-point SEMS screw, 5 mm

Name FG
Cable size

2.0 ~ 5.5 mm

2

min.

Grounding method Class D grounding

[2] External

regenerative

unit connector
(Linear movement axis
only)

When a linear movement axis decelerates or moves downward, regenerative
energy is produced. The capacitor and resistor in the controller alone may not
be able to absorb this regenerative energy (in which case an “Error No. 60C,
Power-system overhear error” will generate). In this case, connect a
regenerative unit or units.
Whether or not your system needs one or more regenerative units depends on
the specific application such as the configuration of linear movement axes.
Refer to Appendix, “Number of Regenerative Units to be Connected.”
If all axes are SCARA axes, no regenerative unit is required.

External Regenerative Unit Connector Specifications

Item Overview

Details

Connector

3-pin 2-piece connector by
Phoenix Contact

GIC2.5/3-STF-7.62

Connector name

RB

Size of supplied
cable

1.0 mm

2

(equivalent to

AWG17)

The cable is supplied with
the external regenerative
unit.

Connected unit

External regenerative box

RB+

Regenerative resistance +
(Motor-driving DC voltage)

Terminal
assignments

RB–

Regenerative resistance –
Grounding terminal

Advertising