IAI America XSEL-QX User Manual

Page 249

Advertising
background image

225

Part 4 Commands

z SEIF (Dedicated SCARA command: specify error type for simple interference check zone)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

SEIF

Interference check

zone number

0 or 1 or 2

(Error type)

CP

[Function]

Set the error type specified in operand 2 (see below) as the type of error generated upon
entry into the simple interference check zone specified in operand 1.

Type of error generated upon entry into the simple interference check zone

0: No error
1: Message level error
2: Operation-cancellation level error

(Note 1)

The simple interference check zone is a dedicated SCARA function.

[Example 1]

SEIF

1

2

Advertising