IAI America XSEL-QX User Manual

Page 457

Advertising
background image

433

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

60 Output function selection 314

1

0 ~ 5

0: General-purpose output
1: Absolute-data backup battery voltage-low warning

level or lower (OR check of all axes. Upon detection of
abnormal level, the output will be latched until a
power-ON reset or software reset is executed.)

61 Output function selection 315

0

0 ~ 5

0: General-purpose output

62 For

future

extension

(Change prohibited)

0

0 ~ 299

63 For

future

extension

(Change prohibited)

0

0 ~ 299

64 Physical input port number

for axis-3 brake forced
release

0 0

~

299

Forcibly unlock the brake when the applicable port is ON
(be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is

specified)

* The synchro slave axis will follow the synchro master

axis.

65 Physical input port number

for axis-4 brake forced
release

0 0

~

299

Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is

specified)

* The synchro slave axis will follow the synchro master

axis.

66 Physical input port number

for axis-5 brake forced
release

0 0

~

299

Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is

specified)

* Valid only for the 6-axis type.

67 Physical input port number

for axis-6 brake forced
release

0 0

~

299

Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is

specified)

* Valid only for the 6-axis type.

68~

69

(For extension)

0

70 Unaffected

general-purpose

output area number (MIN)
when all operations/
programs are aborted

0 0

~

599

* Important: Outputs in this area must be operated under

the responsibility of user programs including the “I/O
processing program at operation/program abort.”
Outputs outside this area will be forcibly turned OFF.
(Invalid if “0” is set)

71 Unaffected

general-purpose

output area number (MAX)
when all
operations/programs are
aborted

0 0

~

599

72 Unaffected

general-

purpose output area
number (MIN) when all
operations are paused
(servo-axis soft interlock +
output-port soft interlock)

300

0 ~ 599

* Important: Outputs in this area must be operated

(including recovery) under the responsibility of user
programs including the “I/O processing program at
all operations pause.” Outputs outside this area will
be forcibly turned OFF, reflecting/holding the results
of operations performed while all operation pause is
effective (only during automatic operation). (Invalid
if “0” is set)

73 Unaffected

general-

purpose output area
number (MAX) when all
operations are paused
(servo-axis soft interlock +
output-port soft interlock)

599

0 ~ 599

74 Number of TP user output

ports used (hand, etc.)

0

0 ~ 8

Referenced by TP.
(Invalid if “0” is set)

75 TP user output port start

number (hand, etc.)

0

0 ~ 599

Referenced by TP.

76 AUTO-mode

physical

output port number

0

0 ~ 599

(Invalid if “0” is set)

77 Input port number for

acceptance permission of
PC/TP servo movement
command

0

0 ~ 299

* Important: Invalid after operation has started.

(Invalid if “0” is set)