Program control – IAI America XSEL-QX User Manual

Page 193

Advertising
background image

169

Part 4 Commands

1.8 Program

Control

z GOTO (Jump)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

GOTO

Tag

number

Prohibited CP

[Function]

Jump to the position of the tag number specified in operand 1.

(Note 1)

A GOTO command is valid only within the same program.

(Note 2)

Do not create a program containing an indefinite loop of continuous movement commands
(refer to Chapter 4 in Part 4) using the TAG-GOTO syntax. It will result in an accumulation
of coordinate conversion errors.

[Example 1]

TAG

1

Set a tag.

:

:

:

GOTO

1

Jump to tag 1.

Using a GOTO command to branch out of or into any of the syntaxes listed below is prohibited.

Since the maximum number of nests is defined for each conditional branching command or subroutine call,
a nest will be infinitely repeated if an ED

…… is not passed, and a nest overflow error will generate. In the

case of palletizing setting, an error will generate if the second BGPA is declared after the first BGPA
declaration without passing an EDPA.

(1) IF

…… or IS…… and EDIF syntax

(2) DW

…… and EDDO syntax

(3) SLCT and EDSL syntax
(4) BGSR and EDSR syntax
(5) BGPA and EDPA syntax

z TAG (Declare tag)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Prohibited Prohibited TAG

Tag

number

Prohibited CP

[Function]

Set the tag number specified in operand 1.

[Example 1]

Refer to the section on GOTO command.