Part 2 Operation

(2) Timing

chart

[1] Start of program

Ready output

Program 1

Program 2

Program number
input

External start
input

T1: Duration after the ready output turns ON until input of

external start signal is permitted
T1 = 10 msec min.

T2: Duration after the program number is input until input of

external start signal is permitted
T2 = 50 msec min.

T3: Input duration of external start signal

T3 = 100 msec min.

[2] Start of program by auto program start

* When I/O parameter No. 33 is set to “2”

Ready output

Input of input
function 003

Auto program
start

T1: Time after the ready output is turned ON until input

function 003 can be input
T1 = 10 msec min.

* Auto program start:

Set the program you want to start automatically in Other
parameter No. 1, “Auto start program number.”

[3] Soft reset signal

* When I/O parameter No. 31 is set to “1”

Ready output

Input of input
function 001

Program starting

T1: Time after the ready output is turned ON until input

function 001 can be input
T1 = 10 msec min.

T2: Time until the soft reset signal starts functioning

T2 = 1 sec min.

T3: Time after the soft reset signal is cancelled until the

ready signal is output

[4] Servo ON signal

* When I/O parameter No. 32 is set to “1”

Ready output

Input of input
function 002

Servo ON

T1: Time after the ready output is turned ON until input

function 002 can be input
T1 = 10 msec min.

T2: Interval after the servo is turned off until it is turned on

again
T2 = 1.5 sec min.

[5] When the recovery type after emergency stop or enabling operation is set to “Operation continued”

* When other parameter No. 10 is set to “2”

Set I/O parameter No. 35 to “1” (Operation pause reset signal)
Set I/O parameter No. 44 to “1” (Drive-power cutoff reset input)

Program starting

Emergency stop

Drive-source
cutoff reset

Pause reset

T1: Time after the emergency stop input is cancelled until

the drive-source cutoff reset signal can be input
T1 = 2 sec min.

T2: Drive-source cutoff reset input time

T1 = 10 msec min.

T3: Pause reset input time

T1 = 10 msec min.