I/o, flag operation – IAI America XSEL-QX User Manual

Page 182

Advertising
background image

158

Part 4 Commands

1.7 I/O, Flag Operation

z BT

……

(Output port, flag operation)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

BT

…… Output,

flag

(Output,

flag)

CP

[Function]

Reverse the ON/OFF status of the output ports or flags from the one specified in operand 1
through the other specified in operand 2.

(Note)

A dedicated output (system output), other than a general-purpose output, cannot be
specified for operand 1 or 2.

BT

……

ON

Switch the status to ON.

OF

Switch the status to OFF.

NT

Reverse the status.

[Example 1]

BTON

300

Turn ON output port 300.

[Example 2]

BTOF

300

307

Turn OFF output ports 300 through 307.

[Example 3]

LET

1

600

Assign 600 to variable 1.

BTNT

*1

Reverse the content of variable 1 (flag 600).

[Example 4]

LET

1

600

Assign 600 to variable 1.

LET

2

607

Assign 607 to variable 2.

BTON

*1

*2

Turn ON the flags from the content of variable 1 (flag
600) through the content of variable 2 (flag 607).