Application – IAI America XSEL-QX User Manual

Page 54

Advertising
background image

30

Part 1 Installation

2. Explanation of Codes Displayed on the Panel Window

2.1 Application

Display Priority

(*1)

Description

1

AC power is cut off (including momentary power failure or drop in power
source voltage).

1

System

down

level

error

2

Writing data to the flash ROM.

3

Emergency

stop

is

being actuated (except during the update mode).

4

Enable switch (deadman switch/safety gate) OFF (except in the update mode)

5

Cold

start

level

error

5

Cold

start

level

error

5

Operation

cancellation

level

error

5

Operation

cancellation

level

error

6

Waiting for a drive source cutoff reset input (except during the update mode).

6

Operation is paused and waiting for a restart signal (except during the update
mode)

7

All servo axes are interlocked (except during the update mode)

8

Message

level

error

8

Message

level

error

9

Core

update

mode

9

Core update is in progress

9

Core

update

has

completed

9

Slave

update

mode

9

Slave

update

is

in

progress

9

Slave

update

has

completed

9

A program is running (last started program). *** indicates the program number.
(Controller with increased memory size (with gateway function))

9

A program is running (last started program). ** indicates the program number.
(Controller with increased memory size)

9

Initialization

sequence

number

9

Debug

mode

9

Ready

status

(auto

mode)

9

Ready

status

(manual

mode)

(*1) The priority increases as the number decreases.