IAI America XSEL-QX User Manual

Page 497

Advertising
background image

473

Appendix

Descripti

on Action

Parameter

setti

ng

Manipul

ation/operati

on

Want to output signal

w

h

en al

l valid

linear movement axes are at their

home.

Output port No. 304 can be set as a

signal indicati

ng that all val

id l

inear

movement axes are at their home.

Note: Do not use a HOME command

w

h

en the contr

oller is of the absolut

e

specification.

I/O parameter No. 50 = 1

Output port No. 304

w

ill tur

n ON

w

h

en

all val

id li

near movement axes are at

their hom

e.

Want to output signal

w

h

en al

l valid

linear movement axes have c

o

mplet

ed

home retur

n.

Output port No. 304 can be set as a

signal indicati

ng that all val

id l

inear

movement axes have complet

ed hom

e

return.

I/O parameter No. 50 = 2

Output port No. 304

w

ill tur

n ON

w

h

en

all val

id li

near movement axes have

complet

ed home return.

Want to releas

e brake us

ing

an

ex

ternal input signal.

A gener

al-purpose input port can be set

as a brake forc

ed-rel

eas

e input

(dedic

ated i

n

put). Set a desired input

port number in

the applicable

paramet

er.

Set a desired input port number in the

I/O parameter corresponding

to the

target ax

is number.

Correspondence of

brake-rel

easing

axis num

ber and par

ameter number:

Ax

is 3:

I/O parameter No. 64

Ax

is 4:

I/O parameter No. 65

Ax

is 5:

I/O parameter No. 66

Ax

is 6:

I/O parameter No. 67

Setting ex

am

ple) T

o

set input

port No.

12 as the brak

e forced-rel

eas

e input for

axis 3, set as follo

w

s:

I/O parameter No. 64 = 12

Brake

w

ill be forcibly

released w

h

en

the

applicable port turns ON.

m

Brake of axis 3

w

ill be forcibly

releas

ed

w

h

en

input port No. 12 turns

ON.

Want to retain output status

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open.

Minimum and

maximum port

numbers

indic

ating the output ports

you

w

is

h

to

retain can be set.

I/O parameter No. 70 = Output port

number MIN

I/O parameter No. 71 = Output port

number MAX

Setting ex

am

ple) T

o

retain output ports

from port Nos. 303 through 315, set as

follo

w

s:

I/O parameter No. 70 = 303

I/O parameter No. 71 = 315

m

T

he status of output port Nos. 305

throug

h 31

5

w

ill be retai

ned

w

h

ile

emergenc

y-stop signal

is input or the

safet

y

gate is open.

Advertising
This manual is related to the following products: