200

Part 4 Commands

z SCRV (Set sigmoid motion ratio)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

SCRV

Ratio

(S-motion type)

CP

[Function]

Set the ratio of sigmoid motion control of the actuator in the value specified in operand 1.
The ratio is set as an integer in a range from 0 to 50 (%).
If the ratio is not set using this command or 0% is set, a trapezoid motion will be
implemented.
A SCRV command can be used with the following commands: MOVP, MOVL, MVPI, MVLI,
TMPI, TMLI, JBWF, JBWN, JFWF, JFWN

You can set the S-motion type in operand 2 if the main application version is 0.45 or later.
This setting is valid in PC software version 7.5.0.0 or later and teaching pendant version
1.11 or later.

Value set in operand 2

Description

0 or blank

S-motion A

1

S-motion B (recommended)