495

Appendix

(In the pan

el wind

ow, the thre

e digits aft

er “E” in

dicate an erro

r nu

mber.

)

Error No.

Error name

Description, ac

tion, etc.

A2A

Program in

acti

ve error

T

he s

pecified program is not r

unni

ng.

A2B

Program-run command r

e

fus

al error in AUT

O mode

Programs cannot

be run from the T

P

/PC softw

a

re co

nnecto

r in the AUT

O

mode.

A2C

Program number error

T

he program number is inv

alid.

A2D

Inactive program resumption

error

A resumption request

w

a

s rec

eived for a pr

ogram currently

not running.

A2E

Inactive pro

gra

m pause err

or

A pause re

qu

e

s

t

w

a

s rec

eived for a program currently

not

running.

A2F

Breakp

oint err

or

T

he step number specifi

ed as

a break

poi

nt is inval

id.

A30

Breakpoint setting-count spec

if

ication err

or

T

he number of break

poi

nts to be set e

x

cee

ds

the limit valu

e.

A31

Parameter change value err

or

T

he value of parameter changed is i

n

val

id.

A32

Parameter t

y

pe error

T

he parameter

type is i

n

val

id.

A33

Parameter number error

T

he parameter

number is invalid.

A34

Card-paramet

er buffer read er

ror

Error readi

ng t

he card-

param

eter buffer

A35

Card-paramet

er buffer

w

rite

er

ror

Error

w

riting the card-paramet

er buffer

A36

Parameter ch

a

nge refus

al err

or durin

g op

era

tion

Parameters

cannot

be changed dur

ing oper

ation (pr

ogram

is runni

ng, serv

o is

in

use, etc.).

A37

Card man

ufact

uring/fu

nction i

n

formatio

n

change refus

al err

or

T

he card manufacturing/functi

on

inform

ation

cannot be changed.

A38

Parameter change refus

al err

or during servo

ON

An attempt

w

a

s made to cha

nge a p

a

ramet

er

w

h

os

e chan

ge is not perm

itted

w

h

ile

the servo is ON.

A39

Non-ac

quired c

a

rd par

ameter

change error

An attempt

w

a

s made to change a paramet

er for a card not recogniz

ed at

reset.

A3A

Device number

error

T

he device number is invalid.

A3C

Memor

y

initi

ali

zation t

y

pe specification

error

T

he specified

memor

y

initi

ali

zation t

y

pe is i

n

vali

d.

A3D

Unit t

y

pe error

T

he unit type is

invali

d.

A3E

SEL

w

rite data

ty

pe s

pecific

ati

on error

T

he specified

SEL

w

rite data

ty

pe is i

n

valid.

A3F

Flash-ROM

w

ri

te refusal error

during program

run

T

he

flash ROM cannot be

w

ritten

w

h

ile a pr

ogram is runni

ng.

A40

Data change r

e

fusal err

or dur

ing flas

h ROM w

rit

e

Data

can

not be

chang

ed

w

h

ile

the flash ROM is bein

g

w

ritte

n.

A41

Dupl

icate flas

h

-ROM

w

rite co

mmands refus

al error

Another flas

h-

ROM

w

rite command

w

a

s received

w

h

ile the flash ROM

w

a

s bei

ng

w

ritten.

A42

Direct monitor

prohi

biti

on erro

r during fl

ash R

O

M

w

rite

Direct

monitor i

s

prohi

bited

w

h

ile the flas

h R

O

M is being

w

ritten.

A43

P0/P3-area dir

ect monitor prohibition err

or

Direct monitor i

n

the P0/P3 ar

eas is pro

hib

ite

d.

A44

Point-d

ata cou

nt specificati

on

error

T

he specified number of point data is inv

ali

d.

A45

S

y

mbol-rec

ord

count spec

ification error

T

he specified n

u

mber of s

y

m

b

ol records is i

n

valid.

A46

Variable-

data c

ount spec

ificati

on error

T

he specified number of vari

able data is invalid.

A48

Error-detai

l quer

y

t

y

pe 1 error

Error-detai

l quer

y

t

y

pe 1 is invalid.

A49

Error-detai

l quer

y

t

y

pe 2 error

Error-detai

l quer

y

t

y

pe 2 is invalid.

A4A

Monitori

ng data t

y

pe error

T

he data type f

o

r monitori

ng data quer

y is i

n

v

a

lid.

Advertising