Use examples of key parameters – IAI America XSEL-QX User Manual

Page 495

Advertising
background image

471

Appendix

9.

Use Examples of Key Pa

rameters

You can add

functions to those availabl

e under

the factory settings or

set dedi

cated functions to I/O ports,

by changi

ng

the pa

rameter values.

Before changing a paramet

er, be sure to read the

correspondi

ng section in the Li

st of Paramet

ers.

Descripti

on Action

Parameter

setti

ng

Manipul

ation/operati

on

Want to prevent errors relating to the

standar

d I/O b

oard and optional boards

(DeviceNet, CC-Link, etc.).

(Want to perform trial operation

w

hen

boar

ds are not

w

ired, etc.)

I/O-board error

monitor can be disabled

to prevent errors from occurring.

Set “0” in the I/O parameter

corresponding

to the I/O board

w

h

os

e

error monitor

you

w

ish to disable.

Standar

d I/O (I/O1): I/O parameter No.

10 = 0

Ex

panded I/O1 (I/O2): I/O parameter

No. 11 = 0

Ex

panded I/O2 (I/O3): I/O parameter

No. 12 = 0

Ex

panded I/O3 (I/O4): I/O parameter

No. 13 = 0

Set “0” in I/O p

a

rameter Nos.

10 and 11

to disable error

monitor for the standard

I/O (

I/O1) and expanded I/O1 (I/O2)

boar

ds, respec

tively

.

Note: T

o

operate a disabled I/

O board,

be sure to revert the parameter setting

to “1.”

Want to exec

ute restart (soft

w

are

reset) using an exter

nal i

nput

signal.

Input port No. 1 can be set as

a restart

input.

I/O parameter No. 31 = 1

T

u

rning ON input port No. 1 for at least

1 second

w

ill ex

ec

ute restart.

Want to exec

ute servo ON usi

ng an

ex

ternal input signal.

Input port No. 2 can be set as

a servo

ON input.

I/O parameter No. 32 = 1

Servo ON

w

ill

be ex

ecuted at

the ON

edge of input port No. 2. Servo OFF

w

ill

be exec

uted at

the OFF edge.

Want to exec

ute auto program

start

using

an exter

nal input signal

.

(Under the def

ault setting, the specified

program

w

ill restart upon po

wer ON or

restart (soft

w

ar

e reset) in the

AUT

O

mode.) (More s

teps

w

ill be required to

execute auto program start.)

Input port No. 3 can be set as

an auto

program start input.

I/O parameter No. 33 = 2

T

he specified program

w

ill start at the

ON edge of input port No.3. The

program

w

ill b

e

aborted at the

OFF

edg

e.

Want to exec

ute paus

e usin

g

an

ex

ternal input signal.

Input port No. 6 can be set as

a pause

input.

Input port No. 5 can be set as

a pause

reset input.

I/O parameter No. 36 = 1

I/O parameter No. 35 = 1

T

u

rning OFF input port No. 6 w

ill

execute paus

e. Pause

w

ill be r

e

set at

the ON edge

of input port No.

5 after

turning ON input port No. 6.

(Input port No. 6 is al

w

a

ys ON.)

Want to reset errors using an

exter

nal

input si

gnal (er

rors of operati

on-

cancel

lati

on level or lo

w

e

r).

Input port No. 13 can be set as an error

reset input.

I/O parameter No. 43 = 2

Errors

w

ill be reset at the ON edge of

input port No 13.

Advertising