Part 1 Installation

2. Safety Circuit for PX Type (Standard Specification) Controller

The PX type controller has a built-in drive source cutoff circuit just like IAI’s other controllers.
The drive source cutoff circuit consists of a relay and conforms to safety category B. If your equipment
must meet a higher safety category, use the QX type (global specification) controller explained later.
Connect the control power supply and motor power supply to the same power source and also turn on/off
the control power supply and motor power supply at the same time.
The teaching pendant port can be connected to either an IAI’s standard teaching pendant or ANSI
teaching pendant. Note, however, that redundant safety circuits cannot be configured even if an ANSI
teaching pendant is used.
Set the teaching pendant type switch located above the teaching pendant connector to the position
appropriate for the teaching pendant used. Set the switch to the left for an ANSI teaching pendant, or to
the right for IAI’s standard teaching pendant.
Note: If the teaching pendant type switch is not set properly, the safety gate switch will not function.
The emergency stop line and enabling line are driven by the controller’s internal power supply. It should
be noted that the safety circuit cannot be driven by an external power source.
Do not use the internal power supply provided for the system I/O connector, for any other purpose. It may
damage the equipment or cause it to malfunction.

The tables below list the signals and wiring methods of the safety circuit interface connector.

System I/O Connector for PX Type

Item Overview

Details

COMBICON (2-row, 9-pin)

MCD1.5/9-G1-3.5P26THR (by Phoenix Contact)

Cable end connector

FMC1.5/9-ST-3.5

Connector

Applicable cable size

0.2 to 1.3 mm

2

(AWG24-16)

Terminal Assignments

Pin

No.

Signal

name

Overview Details

9

DET

IN

Not connected

Not used

8 IN

To external EMG

Emergency-stop detection input

7

EMGin

+24 V

24 V power output for emergency-stop
detection input

6 line+

Shorted
Wired before shipment

5

EMG1

line-

To external EMG

Emergency stop switch 1
Wire circuit 1 connected to EMG of the TP

4 line+

Not connected

3

EMG2

line- Not

connected

Not used

2 Out+

Not connected

Left

1

SDN

Out- Not

connected

External relay drive cutoff contact outputs

18

DET

+24 V Not connected

Not used

17 IN

To external ENB

Enable detection input

16

ENBin

+24 V

24 V power output for enable detection input

15 line+

Shorted
Wired before shipment

14

ENB1

line-

To external ENB

Enable switch 1 (safety gate, etc.)
Wire circuit 1 connected to ENB of the TP

13 line+

Not

connected

12

ENB2

line- Not

connected

Not used

11 Out+

Right

10

RDY

Out-

May be used if
necessary

Ready signal contact outputs (dry contacts)
(for inductive load of up to 400 mA)