Part 4 Commands

z TMRW (Set READ/WRIT timeout value)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

TMRW

Read timer

setting

(Write timer

setting)

CP

[Function]

Set a timeout value used with a READ/WRIT command.
The timer setting specified in operand 1 will set the maximum time the program will wait for
the character string read to end when a READ command is executed.
If the end character could not be read before the timer is up during the execution of the
READ command, a timeout will occur and the program will move to the next step.
(Whether or not a timeout has occurred can be checked from the return code (variable 99
based on the factory setting) that will be stored in a local variable immediately after the
READ command is executed.)
Setting the timer to “0” will allow the READ command to wait infinitely, without timeout, until
the end character is read.
The timer setting is input in seconds (setting range: 0 to 99.00 seconds) including up to two
decimal places.
A variable can be specified indirectly in operand 1.

(Note)

TMRW is set to “0” in the default condition before TMRW setting is performed.

[Example]

SCHA

10

Set LF (=10) as the end character.

TMRW

30

Set the READ timeout value to 30 seconds.

OPEN

1

Open

channel

1.

READ

1

2

Read the character string from channel 1 to column 2
until LF is read.

TRAN

1

99

Assign the return code to variable 1.

CLOS

1

Close the channel.

Read completes successfully within 30 seconds

o Variable No. 1 = 0

Timeout occurs

o Variable No. 1 = 1

* The return code of READ command may not be limited to 0 or 1. The variable to

store the return code can be set in “Other parameter No. 24”. Refer to the
explanation of READ command for details.

The timer setting specified in operand 2 sets the timeout value (maximum time to wait
for completion of send) to be applied when a WRIT command is executed (= maximum
time to wait for send based on flow control).
The WRIT timer setting is effective only for standard SIOs (channel 1 or 2 supporting
flow control).

The timer setting specified in operand 2 sets the timeout value (maximum time to wait
for completion of send) to be applied when a WRIT command is executed (= maximum
time to wait for send based on flow control) (arbitrary).
The WRIT timer setting is effective only for standard SIOs (channel 1 or 2 supporting
flow control).
TMRD used in the X-SEL-JX/KX type controller is treated as TMRW in the X-SEL-
PX/QX type controller. If a program file created for an X-SEL-JX/KX controller is
transferred to an X-SEL-PX/QX controller, the PC software will automatically convert
“TMRD” to “TMRW” before the file is transferred.