background image

346

Part 4 Commands

A

B

C

D

E

F

G

H

Setting example of simple interference check zone
Define simple interference check zone Nos. 1, 2 and 3 as follows:

a. Set the area inside a rectangular solid as

simple interference check zone No. 1.
(A): Xb = 475, Yb =

–50, Zb = 150, Rb = 0

(G): Xb = 400, Yb =

50, Zb = 200, Rb = 180

If Rb is outside the range of 0 to 180 , entry
into this rectangular solid area will not be
detected.

b. Set an area with Yb of 425 mm or more as

simple interference check zone No. 2.

c. Set an area with Xb of –400 mm or less and

Zb of 130 mm or more as simple interference
check zone No. 3.

The figure below shows the edit screen for definition data of simple interference check zone on the
PC software for horizontal articulated robot, where simple interference check zone Nos. 1, 2, and 3
are set:

Simple
interference
check zone
No. 1

Simple
interference
check zone
No. 2

Simple interference
check zone No. 3

+Xb

Xb = 475

Xb = 400

–Yb

+Yb

Yb = 425

Xb = –400

Zb = 0

Zb = 130

Advertising