19. Movement by External Position Data Input (for Linear Axes)

Description

Receive from the host device an absolute value indicating the position data to be used in the movement,
and move the actuator accordingly.

Example of Use

Use an INB command to read position data as a BCD via an input port. The BCD value to be received has
four digits, with the last digit specifying a decimal place. Axis 1 is moved.
Example: If the value of BCD is “1234,” the axis will move to the position at 123.4 mm.

Flow Chart Input

assignment

Output

Application Program

Comment

Home return

Set a speed.

Destination of GOTO

Wait for a start input.

Read the position to move to.

Copy to a real variable to add a decimal point.

Divide by 10 to add a decimal point.

Assign the data to axis 1 corresponding to position
No. 1000

.

Moving complete signal turns OFF

Move to the assigned position.

Movement complete signal turns ON

Jump to TAG1.

Port

Description

Completion of movement by 303

1 Start

input

15 0.1

mm

16 0.2

mm

17 0.4

mm

18 0.8

mm

19 1

mm

20 2

mm

21 4

mm

22 8

mm

23 10

mm

24 20

mm

25 40

mm

26 80

mm

27 100

mm

28 200

mm

29 400

mm

30 800

mm

Start