Clkset1, E) to, Stfclr – Cirrus Logic EP93xx User Manual

Page 144: Rsvd: there are no readable bits in this register

Advertising
background image

5-18

DS785UM1

Copyright 2007 Cirrus Logic

System Controller
EP93xx User’s Guide

5

5

5

STFClr

Address:

0x8093_001C - Write

Definition:

Writing to the STFClr location will clear the CLDFLG, WDTFLG and RSTFLG
in the register,

“PwrSts” on page 5-14

. Any data written to the register triggers

the clearing.

Bit Descriptions:

RSVD:

There are no readable bits in this register.

ClkSet1

Address:

0x8093_0020 - Read/Write

Definition:

The ClkSet1 system control register is one of two register that control clock
speeds.

Note: When a write is performed to the ClkSet1 location, it must be immediately followed by 5

NOP instructions. This is needed to flush the instruction pipeline in the ARM920T core.
Writing to this register will cause the the device to enter Standby for between 8 ms to
16 ms. Reading from this register will not cause an entry into Standby mode.

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

PLL1_X2IPD:

These 5 register bits set the input divider for PLL1
operation. On power-on-reset the value is set to 00111b (7
decimal).

Note: The value in the register is the actual coefficient minus one.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

FCLK DIV

SMC ROM

nBYP1

HCLK DIV

PCLK DIV

PLL1_PS

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

PLL1 X1FBD1

PLL1 X2FBD2

PLL1 X2IPD