DS785UM1

Copyright 2007 Cirrus Logic

Universal Serial Bus Host Controller
EP93xx User’s Guide

1

1

1

1

11

OCIC:

PortOverCurrentIndicatorChange. This bit is valid only if
overcurrent conditions are reported on a per-port basis.
This bit is set when Root Hub changes the
PortOverCurrentIndicator bit. The HCD writes a “1” to
clear this bit. Writing a “0” has no effect.
0 = no change in PortOverCurrentIndicator
1 = PortOverCurrentIndicator has changed

PRSC:

PortResetStatusChange. This bit is set at the end of the
10 ms port reset signal. The HCD writes a “1” to clear this
bit. Writing a “0” has no effect.
0 = port reset is not complete
1 = port reset is complete

USBCfgCtrl

Address:

0x8002_0080 - Read/Write

Default:

0x0000_0000

Definition:

Used to implement some input signals to USB host controller for configuration
through software.

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

TPOC:

When asserted by software, the corresponding port will
enter DISCONNECT state. These bits must be cleared
before the ports can be reused.

TRCS:

Inverted internally and sent out as APP_CntSelN signal to
uhostc_top. Internally known as TicRegCntSel.
APP_CntSelN is used for selecting the counter value for
either simulation or real-time for the 1 ms frame duration
used internally. It should be usually set to “0”. Setting it to
“1” will cause the internal counter count to be a partial full
count.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

TRCS

TPOC

RSVD