UART1 With HDLC and Modem Control Signals
EP93xx User’s Guide

1

4

1

4

14

Default:

0x0000_0000

Definition:

Modem Control Register

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

0:

Must be written as “0”.

LOOP:

Activate internal modem control loopback function. This
internal loopback only affects the hardware handshake
signals. Use the UART1Ctrl LBE bit to loopback the serial
data.
When high, modem control outputs RTSn and DTRn are
forced high (inactive), and modem control inputs are
driven by outputs:
DSR = DTR
CTS = RTS
RI2 = OUT1
DCD = OUT2

OUT2:

OUT2 function. Used for internal loopback.

OUT1:

OUT1 function. Used for internal loopback.

RTS:

RTS output signal:
1 - RTSn pin low
0 - RTSn pin high

DTR:

DTR output signal:
1 - DTRn pin low
0 - DTRn pin high

UART1ModemSts

Address:

0x808C_0104 - Read Only

Default:

0x0000_0000

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

DCD

RI

DSR

CTS

DDCD

TERI

DDSR

DCTS