Cirrus Logic EP93xx User Manual

Page 622

Advertising
background image

17-26

DS785UM1

Copyright 2007 Cirrus Logic

IrDA
EP93xx User’s Guide

1

7

1

7

17

address of all ones are broadcast frames, and are always matched regardless
of the value in the AMV. The AMV may be written at any time, allowing the
address match value to be changed during active receive operation.

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

AMV:

Address Match Value.

IrFlag

Address:

0x808B_008B - Read Only

Default:

0x0000_0000

Definition:

IrDA Flag Register. Contains the nine read only flags which indicate the
current state of the IrDA Interface.

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

TBY:

Transmitter Busy Flag.
0 - Transmitter is idle, or disabled, or an abort is being
transmitted.
1 - Transmit logic is currently transmitting a frame.

RIF:

Receiver In Frame.
0 - Receiver is in preamble/start flag or is in hunt mode.
1 - Receiver is in a frame.

RSY:

Receiver Synchronized Flag.
0 - Receiver is in hunt mode.
1 - Receiver logic is synchronized within the incoming
data.

EOF:

End of Frame.
0 - Current frame is not completed.
1 - The word in the receive buffer contains the last byte of
data within the frame. When the last word in the current
frame is read this bit is cleared.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

TBY

RIF

RSY

EOF

WST

WST

FRE

ROR

CRE

RAB