Timer1clear, Regi, Timer2clear – Cirrus Logic EP93xx User Manual
Page 639: Timer3clear

DS785UM1
18-5
Copyright 2007 Cirrus Logic
Timers
EP93xx User’s Guide
1
8
1
8
18
Address:
Timer3 - 0x8081_0084 - Read Only
Reset Value:
0x0000_0000
Definition:
The Value location gives the current value of the timer. When the Timer Load
register is written to, the Value register is also updated with this Load value.
Bit Descriptions:
Value:
Current value of the timer.
Timer1Clear,
Timer2Clear,
Timer3Clear
Address:
Timer1 - 0x8081_000C - Write Only
Timer2 - 0x8081_002C - Write Only
Timer3 - 0x8081_008C - Write Only
Reset Value:
Not defined.
Definition:
Writing any value to the Clear location clears an interrupt generated by the
timer.
Bit Descriptions:
RSVD:
This register has no readable bits. It is just a write trigger.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RSVD
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RSVD