Cirrus Logic EP93xx User Manual

Page 628

Advertising
background image

17-32

DS785UM1

Copyright 2007 Cirrus Logic

IrDA
EP93xx User’s Guide

1

7

1

7

17

MISR

Address:

0x808B_0080 - Read/Write

Default:

0x0000_0000

Definition:

MIR Status Register.

Bit Descriptions:

RSVD:

Reserved. Unknown During Read.

RFL:

Receive Frame Lost. Set to a “1” when a ROR occurred at
the start of a new frame, before any data for the frame
could be put into the receive FIFO. This bit is cleared by
writing a “1” to this bit. This occurs if the last entry in the
FIFO already contains a valid EOF bit from a previous
frame when a FIFO overrun occurs. The ROR bit cannot
be placed into the FIFO and all data associated with the
frame is lost.

RIL:

Receive Information Buffer Lost. Set to a “1” when the last
data for a frame is read from the receive FIFO and the
RFC bit is still set from a previous end of frame. This bit is
cleared by writing a “1” to this bit. This is triggered if the
RFC bit is already set before the last data from a frame is
read from the IrData register. It indicates that the data from
the IrRIB register was lost. This can occur if the CPU does
not respond to the RFC interrupt before another (short)
frame completes and is read from the IrData register by
the DMA controller.

RFC:

Received Frame Complete. Set to “1” when the last data
for a frame is read from the receive FIFO (via the IrData
register). This event also triggers the IrRIB to load the
IrFlag and byte count. This bit is cleared when the IrRIB
register is read.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

RSVD

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

RSVD

RFL

RIL

RFC

RFS

TAB

TFC

TFS