Cirrus Logic EP93xx User Manual

Page 470

Advertising
background image

11-30

DS785UM1

Copyright 2007 Cirrus Logic

Universal Serial Bus Host Controller
EP93xx User’s Guide

1

1

1

1

11

Default:

0x0000_0000

Definition:

Describes the root hub.

Bit Descriptions

RSVD:

Reserved. Unknown During Read.

DR:

DeviceRemovable. Each bit is dedicated to a port of the
Root Hub. When cleared, the attached device is
removable. When set, the attached device is not
removable.
bit 0: Reserved
bit 1: Device attached to Port #1
bit 2: Device attached to Port #2
bit 3: Device attached to Port #3

PPCM:

PortPowerControlMask: Each bit indicates if a port is
affected by a global power control command when
PowerSwitchingMode is set. When set, the port’s power
state is only affected by per-port power control
(Set/ClearPortPower). When cleared, the port is controlled
by the global power switch (Set/ClearGlobalPower). If the
device is configured to global switching mode
(PowerSwitchingMode=0), this field is not valid.
bit 0: Reserved
bit 1: Ganged-power mask on Port #1
bit 2: Ganged-power mask on Port #2
bit 3: Ganged-power mask on Port #3

HcRhStatus

Address:

0x8002_0050

Default:

0x0000_0000

Definition:

Root hub status.

Bit Descriptions:

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

CRWE

RSVD

CCIC

LPSC

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

DRWE

RSVD

OCI

LPS