Creating and Editing Ladder Program Files

6–15

Search and Replace

Note

You cannot search for an indirect address; however, you can search and replace
components within the indirect address. For example, if you are replacing N7:0
with R6:2.POS, the indirect address F8:[N7:0] becomes F8:[R6:2.POS].

For indexed addresses, the # sign is ignored when performing a search and replace
for instructions or addresses. For example:

If the address is:

and you search for:

and replace with:

the result is:

#N7:1

N7:1

#N7:4

#N7:4

N7:1

N7:1

#N7:4

N7:4

#N7:4

#N7:4

N7:5

#N7:5

N7:4

#N7:4

N7:5

N7:5

To search for and replace an instruction or address, begin at the search screen.

1.

Press

CONFIG

OFFLINE

CONFIG

SEARCH

TYPE

F1

, until Search & Replace Instr/Addr appears in the search type

field.

2.

Press

CONFIG

OFFLINE

CONFIG

SEARCH

FOR

F2

. Enter the instruction type by doing one of the following:

type in the search string and press

[ENTER]

press the appropriate function key

3.

Press

CONFIG

OFFLINE

CONFIG

REPLACE

WITH

F3

. Select the replace string and press

[ENTER]

.

4.

Press

CONFIG

OFFLINE

CONFIG

START

SEARCH

F4

. The system moves the cursor to the first occurrence of the

search object and prompts you to either

Replace, Skip, Quit, or

All

. If no match is found, the cursor position does not change and the

following message is displayed:

SEARCH PATTERN NOT FOUND

If replacements are made, the following message is displayed:

REPLACEMENTS HAVE BEEN MADE

.