Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual

Page 394

Advertising
background image

Transferring Program Files

21–21

9.

To transfer the program file to the APS terminal, press

CONFIG

OFFLINE

CONFIG

DOWNLOAD

F3

. The

message

Download to Processor?

will appear. Press either

CONFIG

OFFLINE

CONFIG

YES

F2

to continue or

CONFIG

OFFLINE

CONFIG

NO

F4

to abort the procedure.

The message

Downloading File

appears on the HHT display as the file is

transferred to the APS terminal. When the transfer is complete, the APS
terminal displays the following menu:

PROGRAM TRANSFER COMPLETED
Press <ESC> to exit

Term. Addr: 0

Emulation: 5/01

ROCKWELL SOFTWARE INCORPORATED

9323 SERIES SOFTWARE

SLC-500 PROGRAM TRANSFER UTILITY

File Name : EXAMPLE .ACH

A total of

4 data, 4 program, and 2 force table(s)
20 Words in 4 Data Files, 78 Words in 4 Program Files,
2 Words in 2 Force Tables.

There are

0 undefined data and 0 undefined program file(s).

10. This completes the program file transfer procedure. At the APS terminal press

[ESC][ESC][ESC]

to return to the main menu.