Preface – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 412

Preface
Advanced Programmming Software User Manual
A–18
Display Message
Recommended Action
Description
PURGE OF EXISTING DATABASE
FAILED
The deletion of the existing database
failed.
Verify that the DOS path contains
(ipds\lis\slc500) and that the file is not
write protected.
RESOURCE IS NOT AVAILABLE
The device at the current node is unable
to process the request because the
program in the device was not compiled
for single step debug.
Activate single step debug and resave
the current image.
SAME ADDRESS FOUND, ONLY
ADDRESS CURRENTLY IN DATABASE
While documenting a program function
key next address" was pressed and
only one address comment exists.
Informational message. No action
necessary.
SAME SYMBOL FOUND, ONLY
SYMBOL CURRENTLY IN DATABASE
While documenting a program function
key next symbol" was pressed and only
one symbol exists.
Informational message. No action
necessary.
SAVE ABORTED, PROGRAM IS
READĆONLY
An attempt was made to save changes
made to a read only program.
Informational message. No action
necessary.
SCANNED I/O IS TOO LARGE
A scanned I/O value was entered which
exceeded the actual Input or Output
image size for the selected module.
Change to a valid size and retry the
function.
SEARCH FOR OPERAND FAILED
During create reports an error occurred
while attempting to search the cross
reference database.
Check your disk space by running
CHKDSK" from your DOS prompt. On
successful completion retry the function.
SEARCH FOR XREF OCCURRENCE
FAILED
During create reports an error occurred
while attempting to search for an
existing cross reference database entry.
Check your disk space by running
CHKDSK" from your DOS prompt. On
successful completion retry the function.
SEARCH OF DOCUMENTATION DB
FAILED
During create reports an error occurred
while attempting to search the cross
reference database.
Check your disk space by running
CHKDSK" from your DOS prompt. On
successful completion retry the function.
SELECTED DRIVER CONFLICTS WITH
WINDOWS DRIVER
The serial port (COM1 or COM2) is
already being used by the DHĆ485
INTERCHANGE driver.
Either exit APS (and Windows) and run
ABICSTOP to shut down the
INTERCHANGE/Windows driver, or
select Windows DHĆ485 from the online
configuration menu.
SELECTED PROCESSOR DOES NOT
SUPPORT THIS FEATURE
I/O auto configuration is not available for
the current processor.
Change the processor to an SLC 5/03
and retry the function.
SOFTWARE NOT INSTALLED
PROPERLY
The personalization data entered during
the installation process is missing.
Reinstall the software.
SOURCE DIRECTORY CANNOT BE
THE SAME AS THE DESTINATION
DIRECTORY
The copy to/from the paths are the
same.
Change one of the paths and retry the
function.
STARTING FILE TYPE MUST BE
BEFORE ENDING FILE TYPE
During configuration of report options a
starting file type that is alphabetically
after the ending file type was entered.
Change the file types and retry the
function.