1–13

To edit the file, do the following:

1.

At the DOS prompt type:

edit C:

(INTERCHANGE directory)

\CFG_KT.INI

Note

If this was a new installation, the default INTERCHANGE directory is

\RSI\IC\BIN

. If you installed INTERCHANGE over a previous version, the

default directory is

\ABIC\BIN

.

2.

A description of INTERCHANGE is provided along with the driver
initialization templates. To activate an interface card, edit and uncomment an
option(s) by removing the semicolon at the beginning of the line. The
following examples show an unedited and edited initialization file for the
1784-KT interface card. A listing of the available files begins on page 1–14.

Unedited initialization file for the 1784-KT:

;[DTL_KT.1]

;DEVICE=KT

;MEMORY=D400

;IRQ=5

;STATION=77

;NAME=KT 1

;TERMINATION=ON

Edited initialization file that configures the 1784-KT for port 4:

[DTL_KT.1]

DEVICE=KT

MEMORY=D400

IRQ=5

STATION=77

NAME=KT 4

TERMINATION=ON

Note

See the interface card documentation to determine the correct memory address
and IRQ address.

3.

Once you have edited the required interface cards, save the file and exit.