Monitoring Controller Operation
16–7
Monitoring an Application
A ladder program using an up counter is used as an example in this section. Using
this example, you will see how to:
•
monitor a program file
•
view the data table file
•
change the radices
Monitoring a Program File
1.
Select the file using the arrow keys and then press
CONFIG
OFFLINE
CONFIG
MONITOR
FILE
F8
. The count up bit
(CU or 15), done bit (DN or 13), and overflow bit (OV or 12) energize external
outputs 0, 1, and 2 respectively. External input 0 enables the counter; external
input 1 resets the counter.
F7
F8
GENERAL
UTILITY
Press function key or enter value
S:28/15 =
REM RUN
no forces
EDITS: NONE
PROC Addr 1
DATA
MONITOR
] [
I:0.0
0
(CU)
(DN)
CTU
COUNT UP
Counter
C5:0
Preset
3
Accum
0
] [
C5:0
CU
] [
C5:0
DN
] [
I:0.0
1
(RES)
C5:0
( )
O:0.0
0
( )
O:0.0
1
] [
C5:0
OV
( )
O:0.0
2
END
Rung 0
Rung 1
Rung 2
Rung 3
Rung 4
F6
SEARCH
F9
FORCE
F10
EDIT
F2
F3
CONFIG
DISPLAY
EXIT
F1
CHANGE
MODE
F5
DOCUMNT