Preface

Advanced Programming Software User Manual

16–28

Transmit Enable: This data is mapped to memory location S:34/3 in the SLC 5/04
processor. A 1 in this location allows the SLC 5/04 processor to send out the
information in S:99 on the DH+ link as it’s Global Status Word. A 0 disables
transmitting. You can cursor to this entry and turn on/off Global Status Word
transmission.

Receive Enable: This data is mapped to memory location S:34/4 in the SLC 5/04
processor. A 1 in this location allows the SLC 5/04 processor to collect Global
Status Words from other devices on the DH+ link and stores them in memory
locations S:100–S:163. A 0 disables collection. You can cursor to this entry and
turn on/off Global Status Word collection.

The keys available at the Global Status File display perform the following functions:

Function Key

Description

[F1] Binary Data
[F3] Decimal Data

These keys allow you to change the radix display. Decimal

[F4] Hex/BCD Data

These keys allow you to change the radix display. Decimal

Data is the default radix for the Global Status File.

[F5] ASCII Data
[F9] Save Configuration

Saves the current radix as the new default radix.

[F10] Exit

Returns you to the previous status file screen.