Preface, Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 355

Preface
Advanced Programming Software User Manual
19–4
1.
Access the Force menu functions, by pressing
CONFIG
OFFLINE
CONFIG
FORCE
F9
. The following
function keys appear:
Press a key for desired forcing function
(file 2, rung 0)
REM RUN
no forces
PROC Addr 1
F2
ON
F3
REMOVE
F7
ENABLE
F9
MONITOR
INPUTS
F8
DISABLE
F1
OFF
F4
REMOVE
ALL
F10
MONITOR
OUTPUTS
2.
To install a force ON for the cursored external input file address press
CONFIG
OFFLINE
CONFIG
ON
F2
. (Press
F1 OFF
to install a force OFF.) The following display
appears:
Press a key for desired forcing function
(file 2, rung 0)
REM RUN
forces DISABLED
PROC Addr 1
F2
ON
F3
REMOVE
F7
ENABLE
F9
MONITOR
INPUTS
F8
DISABLE
F1
OFF
F4
REMOVE
ALL
F10
MONITOR
OUTPUTS
( )
O:0
0
END
( )
B3
10
( )
B3
11
] [
B3
11
]/[
B3
12
]/[
B3
10
] [
I:0
1
( )
B3
12
] [
B3
11
] [
I:0.0
1
]/[
B3
10
] [
I:0
1
] [
B3
11
ON
ON
ON
ON
appears with instruction I:0/1 in rungs 0, 1, and 2. The status line indicates
forces DISABLED
. The controller’s Forced I/O LED is flashing.