Preface, Offline config, Adding symbols – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 128

Preface
Advanced Programming Software User Manual
7–12
Function Key
Description
[F1] Delete Comment
[F2] Undelete Comment
Deletes and undeletes comments, lines of comments, and
individual words.
[F3] Delete Line
[F4] Undelete Line
Deletes and undeletes line comments.
[F5] Delete Word
[F6] Undelete Word
Deletes and undeletes word comments.
[F8] Accept/Exit
Allows you to accept the rung comment and exit to the
Document menu functions.
[F9] Next Comment
Saves the current comment and moves the cursor to the
next rung, instruction, or address that you can comment.
[F10] Previous Comment
Saves the current comment and moves the cursor to the
output instruction in the previous rung, instruction, or
address that you can comment.
3.
Press either
CONFIG
OFFLINE
CONFIG
ACCEPT
/ EXIT
F8
, or
CONFIG
OFFLINE
CONFIG
NEXT
COMMENT
F9
, or
CONFIG
OFFLINE
CONFIG
PREV
COMMENT
F10
.
Adding Symbols
A symbol can consist of up to 10 characters. Characters can be the letters A to Z,
numbers 0 to 9, and spaces. Letters are displayed as all caps. Spaces are underlines
(__). Note that you cannot begin a symbol with a numeral (0 to 9).
The following shows the offline Monitor file display of processor file
EXAMPLE2
.
Assume the display is presently configured to display symbols. The Configure
Display option is discussed on page 7–25.
1.
To add a symbol to rung 0, press
CONFIG
OFFLINE
CONFIG
DOCUMNT
F5
. The document functions appear.
Press a key for desired document function
(file 2, rung 0)
offline
no forces
File EXAMPLE2
F2
INSTRUC
COMMENT
F10
SAVE
DOCUMNT
F3
ADDRESS
COMMENT
F6
F7
MODIFY
SYMBOL
REMOVE
SYMBOL
F5
EDIT
DBASE
F1
RUNG
COMMENT