Preface, Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 89

Preface
Advanced Programming Software User Manual
5–22
Image to Archive Operation (SLC 5/03 and SLC 5/04 Processors Only)
The Image to Archive option allows you to convert image files to the archive file
directory.
1.
From the File Options menu press
CONFIG
OFFLINE
CONFIG
IMAGE
TO ARCH
F1
. The following menu appears:
Name
Size
Date
DRILL1
9392
09-12-95
DRILL2
9392
10-07-95
EXAMPLE
929
10-07-95
MIXER
10221
10-15-94
ONOFF
9334
08-04-95
PAINTGUN
9261
07-19-94
RPMCALC
8704
04-27-94
SEQUENCE
8684
10-03-95
STOP_GO
8586
09-28-94
TOGGLE
8695
07-19-94
C:\IPDS\TEXT\SLC500
IMPORT PROCESSOR IMAGES
ESC exits
SOURCE:
DESTIN:
F7
DEFINE
DIR
Press a function key
ESC exits/Alt–U aborts changes
F3
SELECT
SOURCE
F1
BEGIN
OPER
F4
ENTER
DESTIN
Function Key
Description
[F1] Begin Operation
Converts the selected processor image to the archive file.
[F3] Select Source
Selects the highlighted file from the directory window and
places a copy in the file field.
[F4] Enter Destination
Prompts you to enter the destination file name.
[F7] Define User Directories
Displays the user directory window. See chapter 3 for more
information.
2.
The external processor image files are shown in the right window. Select the
image file you want to convert by cursoring to the correct file and pressing
CONFIG
OFFLINE
CONFIG
SELECT
SOURCE
F3
.