APS Error Messages

A–3

Display Message

Recommended Action

Description

BRIDGE DEVICE NOT ACTIVE

Inability to attach to a KF3 while going

online with DF1 Full Duplex.

Retry the function.

BRIDGE DEVICE RESPONDED WITH

ERRORS

There is an error in the received packet

from the 1785ĆKA5 interface module.

Retry the function.

CANNOT EDIT THIS RUNG

An attempt was made to edit a replaced

marked rung or modify a deleted marked

rung.

ReĆevaluate your edit attempt.

CANNOT INSERT A RUNG BETWEEN

AN IR PAIR

An attempt was made to insert, append,

or undelete a rung between an inserted

marked rung followed by a replaced

marked rung.

Move the cursor before or after the IR

pair and try to insert, append, or

undelete the next rung.

CANNOT MODIFY DATA TABLE SIZE

DURING ONLINE EDITING

Modification of data table sizes or

creation of new data tables cannot occur

while in an online editing session.

Go offline to change the data table sizes

and retry the function.

CANNOT MODIFY PARAMETER VIA

5/03 PROCESSOR'S CHANNEL 0

An attempt to change a node's owner,

the max. address, node address, or

baud rate of an SLC 5/03 while it was

communicating with APS over channel 0

was made.

Not allowed.

CANNOT MODIFY PROTECTED DATA

FILE DURING ONLINE EDITING

During an online editing session, an

attempt was made to modify data tables

that were constantly protected.

Not allowed. Go offline to either change

the data file protection and retry the

function, or edit the program offline.

CANNOT TRANSMIT - LOSS OF

COMMUNICATIONS

Either the communication interface

module has waited more than 10

seconds to gain access to the send

mailbox or APS has attempted to send a

packet before getting confirmation of the

previous send.

Retry the function.

CAUTION: INDIRECT ADDRESSES

MUST ALREADY EXIST AND BE

PROPERLY REFERENCED

An indirect address was entered into the

ladder program.

Ensure that the necessary data table

addresses are allocated for indirect

addressing.

CAUTION: REMOVING OUTPUT

REFERENCES LEAVES THE

OUTPUTS IN THEIR LAST STATE

Either 1) the Test Edits function key was

pressed and edits do exist in the ladder

program; or 2) an attempt to delete an

instruction was made.

Be aware that changes may result to the

output states when the new assembled

edits become active or when a restore is

performed via quick edits.

CAUTION: VERIFY STATE OF

OUTPUTS WITH DATA MONITOR

You directed APS to assemble all

existing online edits or a quick edit

program.

Be aware that changes may result to the

output states when the new assembled

edits become active or when a restore is

performed via quick edits.

CHANGE BINARY FILE TO

SEQUENTIAL BEFORE ENABLING

SHORT ADDRESSING

An attempt to enable short addressing

failed because the Binary File selection

is set to word/bit.

Change the Binary File selection to

sequential and then retry.