Creating and Printing Reports

10–7

3.

Change the program listing options by pressing the corresponding function key.

Function Key

Description

[F1] Rung Range

Allows you to specify a range of rungs to print. The following

additional options are available:
[F2] Select All - Selects the Starting File through the Ending File.

This includes all rungs in the specified files.
[F3] Single File - Selects the entire contents of a single file.
[F4] Select Range - A range of files and/or rungs within a single file

or multiple files can be selected by entering the delimiter `.' after the

ladder file number. If a rung number is not entered next to the file

number, the entire file will be selected. A valid range entry might

be:

D

4:6 to 2:4

D

2:10 to 3:5

[F2] Power Rail

Toggles between Yes and No, indicating whether the printout will

show the rightĆhand power rail or not. Selecting No saves time in

the printing process.

[F3] Address Comment

Toggles between Yes and No. Yes indicates that

address/instruction comments will be shown. No indicates that

comments will not be shown.

[F4] Address Display

Toggles between Symbol and Address. Symbol indicates that

existing symbols and addresses will be shown. Address indicates

that only addresses will be shown.

[F5] Rung Comment

Toggles between Yes and No, indicating whether rung comments

will be shown.

[F6] Ladder Cross

Reference

Cross reference data for a particular address includes the

instruction type, symbol, address comment, file number, and rung

number of all instructions having that address. Toggles between All,

None, and Outputs Only.
All - Cross reference information for all addresses in a rung appear

directly after the rung.
None - No cross reference information appears.
Outputs Only - Only cross reference information for addresses in

output instructions appear.

[F7] Output Cross

Reference

Cross reference data for a particular input address, indicating the

file and rung number of the first output instruction in the ladder

program having that address. Toggles between Yes and No. Yes

indicates that output cross references will be shown. No indicates

that references will not be shown.

[F9] Save to File

Stores your selected options for future reference. Initial starting and

ending numbers always conform to the files existing in the selected

processor file.