Preface

Advanced Programming Software User Manual

8–14

Depending on the form of protection, one of the following prompts is displayed:

Enter list of files to apply static protection

Enter list of files to apply constant protection

Enter list of files to remove static and/or

constant protection

If you attempt to change the protection of an already protected file, APS detects
this request. In this example, R6:10 is already statically protected. The
following display appears if protection is detected:

FILE

TYPE

LAST ADDRESS

ELEMENTS WORDS

FILE PROTECTION

0

O output

O:2

1

1

1

I input

I:3

2

2

STATIC MEM-MOD

2

S status

S:82

83

83

STATIC MEM-MOD

3

B binary or bit

B3/15

1

1

MEM-MOD

4

T timer

T4:10

11

33

5

C counter

C5:10

11

33

CONSTANT

6

R control

R6:10

11

33

STATIC

7

N integer

N7:255

256

256

8

F floating

F8:0

1

2

PROCESSOR MEMORY LAYOUT

391 data words of memory used in 9 data table files
266 instruction words of memory used in 3 program files
3732 instruction words of unused memory available

File(s) already STATIC Protected. DO you wish to alter protection?

offline

SLC 5/03

File EXAMPLE

DATA TABLE MAP

File 8 only applies to SLC

5/03 OS301, OS302 and

SLC 5/04 OS400, OS401

processors.

F10

NO

F8

YES

The above prompts only appear if you attempt to change the form of protection

for one or more data table files. If you press

CONFIG

OFFLINE

CONFIG

YES

F8

, all of the files in the

list will have their protection changed. If you press

CONFIG

OFFLINE

CONFIG

NO

F10

, the entire

request is cancelled and protection is not changed.

If the file is Constant protected and you want to change it to Static protection,
the prompt:

File(s) already CONSTANT protected. Do you

wish to alter protection?

is displayed.