Preface
Advanced Programming Software User Manual
11–12
Function Key
Description
[F8] Board Address
➀
Allows you to select the board address for the 1784ĆKT(2)
card. Valid values are A000 to D800 in increments of 400 with
the exception of B000 and BC00 (all values in hexadecimal).
The default is A000.
[F9] Save to File
Allows you to save the established parameters to a user
configuration file that APS accesses to automatically set up
these parameters the next time you use the software.
➀
Refer to either the 1784ĆKT or 1784ĆKT2 user manuals for more information about these parameters.
Note
If initialized for a 1784-KT interface card, APS displays the message
Illegal
Data or Parameter Value
during power up if any of the following are true:
•
an invalid board address is programmed
•
memory allocation contention exists
•
the KT module does not exist
•
an invalid or previously assigned interrupt (IRQ) is selected