Preface – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual

Page 206

Advertising
background image

Preface

Advanced Programming Software User Manual

11–12

Function Key

Description

[F8] Board Address

Allows you to select the board address for the 1784ĆKT(2)

card. Valid values are A000 to D800 in increments of 400 with

the exception of B000 and BC00 (all values in hexadecimal).

The default is A000.

[F9] Save to File

Allows you to save the established parameters to a user

configuration file that APS accesses to automatically set up

these parameters the next time you use the software.

Refer to either the 1784ĆKT or 1784ĆKT2 user manuals for more information about these parameters.

Note

If initialized for a 1784-KT interface card, APS displays the message

Illegal

Data or Parameter Value

during power up if any of the following are true:

an invalid board address is programmed

memory allocation contention exists

the KT module does not exist

an invalid or previously assigned interrupt (IRQ) is selected

Advertising