Preface
Advanced Programming Software User Manual
12–6
1.
Begin at the main menu and press
CONFIG
OFFLINE
CONFIG
WHO
F5
, then
CONFIG
OFFLINE
CONFIG
WHO
ACTIVE
F5
. The following
display appears:
0
TERM
(31)
12
24
1
500-20
(31)
13
25
2
500-30
(31)
14
26
3
500-40
(31)
15
27
4
16
28
5
17
29
6
18
30
7
19
31
8
20
9
21
10
22
11
23
F2
STATION
DIAGS
Press a key for desired network function
WHO ACTIVE - Active Station Identification
ESC exits
F1
ONLINE
F3
SET
OWNER
F4
CLEAR
OWNER
F7
MAX
ADDRESS
F8
NODE
ADDRESS
F9
NODE
BAUD
2.
Cursor to the highest numbered node.
3.
Press
CONFIG
OFFLINE
CONFIG
MAX
ADDRESS
F7
and enter the number of the node you are on.
4.
Press
[ENTER]
. If the message:
MAXIMUM NODE ADDRESS VIOLATION
DETECTED
appears, this informs you that APS has detected an active node on
the network with a node address higher than the APS maximum node address.
Note
When you cycle power to an SLC 5/01 Series A processor, the maximum node
address returns to the default selection of 31.
You cannot change the maximum node address of the terminal at this display. If you
attempt to change the address, the message
CURRENT DEVICE IS NOT A
PROCESSOR
appears.