Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual

Page 292

Advertising
background image

Changing Processor Modes

15–11

To test a single rung at a time, do the following:

1.

Press

CONFIG

OFFLINE

CONFIG

SINGLE

STEP

F2

, then

CONFIG

OFFLINE

CONFIG

EXECUTE

STEP

F8

. The processor executes an initialization

scan. The blinking power rail indicates the next rung to be scanned (Rung 2:0).

2.

Press

CONFIG

OFFLINE

CONFIG

EXECUTE

STEP

F8

again. The processor then executes file 2, rung 0. The power

rails on the next rung to be scanned now blink (Rung 2:1).

3.

Repeat step 2 to proceed through your program one rung at a time.

To test a group of rungs, do the following:

1.

Press

CONFIG

OFFLINE

CONFIG

SINGLE

STEP

F2

, then

CONFIG

OFFLINE

CONFIG

SET

END RNG

F1

. Enter the ending file and rung number the

processor is to scan. For example: 2:10 (file 2, rung 10).

2.

Press

[ENTER]

. The processor executes an initialization scan and then

executes from the blinking rung to the specified ending rung. The power rails
on the specified end rung now blink indicating that it is the next rung to be
scanned.

3.

Press

[ENTER]

and scan from the blinking rung through the end of the

program and back to the blinking rung, or enter a new ending file and rung
number and press

[ENTER]

. The processor scans from the existing rung with

blinking power rails to the newly specified end rung.

4.

Repeat step 3 to continue scanning groups of rungs.

To resume processor execution from rung 0 (or start over), exit the Single Step
Test mode and enter the Program mode or any other mode. Then re-enter the
Single Step Test mode.