APS Error Messages

A–9

Display Message

Recommended Action

Description

FATAL DISK ERROR

A failure occurred while trying to load the

data base from disk or trying to save the

data base to disk.

1) Retry the function, 2) restart APS from

the DOS command prompt; then 3)

verify your disk validity by running

CHKDSK." Contact your RSI

representative if the above actions do

not help.

FATAL ERROR - RUNG BRANCH

CONTAINS MORE THAN 75 LEVELS

During create reports a rung was

detected having more than 75 levels on

a branch.

Change the rung to have no more than

75 levels. Retry the function.

FATAL ERROR CLOSING FILE

An unknown error occurred when APS

tried to read from a file.

Either 1) retry the function; 2) restart the

software; 3) reboot the PC; or 4) run

CHKDSK" from the DOS command

prompt.

FATAL ERROR INITIALIZING

DOCUMENTATION FILES

An error occurred during an initialization

of the current data base after you

requested to rename the current file.

1) Retry the function, 2) restart APS from

the DOS command prompt; then 3)

verify your disk validity by running

CHKDSK." Contact your RSI

representative if the above actions do

not help.

FATAL ERROR OPENING FILE

An unknown error occurred when APS

tried to read from a file.

Either 1) retry the function; 2) restart the

software; 3) reboot the PC; or 4) run

CHKDSK" from the DOS command

prompt.

FATAL ERROR READING FROM FILE

An unknown error occurred when APS

tried to read from a file.

Either 1) retry the function; 2) restart the

software; 3) reboot the PC; or 4) run

CHKDSK" from the DOS command

prompt.

FATAL ERROR SAVING

DOCUMENTATION FILES

An error occurred during a save of the

current data base after you requested to

rename the current file.

1) Retry the function, 2) restart APS from

the DOS command prompt; then 3)

verify your disk validity by running

CHKDSK." Contact your RSI

representative if the above actions do

not help.

FATAL ERROR WRITING TO FILE

An unknown error occurred when APS

tried to write to a file.

Either 1) retry the function; 2) restart the

software; 3) reboot the PC; or 4) run

CHKDSK" from the DOS command

prompt.

FATAL INTERNAL ERROR

Either 1) APS was not able to allocate

memory from DOS while you were

reviewing/editing comments or symbols;

or 2) APS was initializing and could not

allocate DOS memory for internal data

storage.

Verify your disk validity by running

CHKDSK" from the DOS command

prompt. We recommend 525K bytes

available for APS 3.01, 550K bytes

available for APS 4.0, 250K bytes

available for APS 5.0, and 300K bytes

available for APS 6.0.