3) setting i/o references – Yaskawa 120 Series I/O Modules User Manual

Page 141

Advertising
background image

3.5 Operations Using MEMOSOFT

3-111

3

(4) The I/O Map Screen will be displayed. Move the cursor to the slot to which the

allocations are to be made.

If the Digital Output (or Input) Module is already mounted, the Module model
description will be displayed on the right.

(5) Press the Shift + ? Keys. A list of Module types will be displayed.

Move the cursor to 120DAO84300 and press the Enter Key to select the Digi-
tal Output Module.

3) Setting I/O References

A screen to allocate I/O (I/O Traffic Cop Screen) will be displayed.

(1) Input the reference number of the first output coil:

Move the cursor to the field for the reference number of the first output coil and
input the reference number. Press the Enter Key.

Fig. 3.22 I/O Map

?

Fig. 3.23 Module Selection

Input 000017.

Fig. 3.24 I/O Traffic Cop Screen

Advertising